WEBVTT

1
00:00:24.600 --> 00:00:28.520
We've already got about 38 man hours of duct work in.

2
00:00:44.300 --> 00:00:47.360
Honey, why don't we put the kids playroom here?

3
00:00:47.620 --> 00:00:49.960
For the tenth time, Ruth. That's where the furnace goes.

4
00:00:49.960 --> 00:01:00.640
I'm afraid I'll have to take the whole thing out, lady.

5
00:01:02.360 --> 00:01:08.700
Now, I think that any day now, somebody's going to come up with a whole new concept in heating.

6
00:01:09.640 --> 00:01:14.900
A system that takes advantage of the tremendous advances in technology that we've seen lately.

7
00:01:15.580 --> 00:01:21.140
Something that'll get rid of the cumbersome equipment that we've had to design into houses so far.

8
00:01:22.100 --> 00:01:26.740
And when that happens, you future architects are going to be...

9
00:01:36.940 --> 00:01:42.060
This is Thermalux Electric Heating, new, from United States gypsum.

10
00:01:43.220 --> 00:01:47.720
People call it the most startling home heating development in the last 20 years.

11
00:02:01.520 --> 00:02:03.700
And this is all there is to it.

12
00:02:04.320 --> 00:02:10.640
These gypsum panels, all by themselves, will give the people in this house the most natural, comfortable, room-by-room heat

13
00:02:10.640 --> 00:02:12.580
they will have ever experienced.

14
00:02:25.180 --> 00:02:26.340
Now, this is how it works.

15
00:02:27.400 --> 00:02:31.460
The basic panel is essentially a standard half-inch gypsum board.

16
00:02:33.180 --> 00:02:38.620
Running down the entire length of the board on both sides is a thin copper electrode.

17
00:02:40.640 --> 00:02:46.620
Now, on this side of the board is a chemically bonded layer of graphite.

18
00:02:46.620 --> 00:02:51.760
It's sandwiched between two sheets of asbestos insulation.

19
00:02:57.140 --> 00:03:05.520
When the Thermalux panels are installed in the ceiling, these copper strips here and here are fitted with connectors.

20
00:03:11.640 --> 00:03:15.560
And then they are wired directly to the power supply of the house.

21
00:03:18.020 --> 00:03:21.960
Now, this layer of graphite acts as a large electrical resistor.

22
00:03:22.540 --> 00:03:29.180
And as the electric current passes through it, 100% of that electric current is transformed instantly into heat.

23
00:03:30.060 --> 00:03:34.560
Now, because the Thermalux resistor spreads the electrical energy over such a large area,

24
00:03:35.040 --> 00:03:38.660
the standard operating temperature of these heating panels is quite low,

25
00:03:38.660 --> 00:03:41.460
about 105 degrees Fahrenheit.

26
00:03:44.920 --> 00:03:49.200
Even after hours of continuous operation, the temperature remains stable.

27
00:03:52.200 --> 00:03:55.040
Now, let's suppose the panel gets wet.

28
00:03:59.220 --> 00:04:03.900
The Thermalux can't short out because the resistance will increase rather than decrease,

29
00:04:03.900 --> 00:04:08.140
and the heat of the Thermalux will evaporate the water in a short time.

30
00:04:09.540 --> 00:04:13.660
The Thermalux system is based upon the concept of radiant heat,

31
00:04:14.160 --> 00:04:18.180
which is much more efficient than the convection system used in other heating.

32
00:04:21.420 --> 00:04:30.600
A radiant heat is like the heat of the sun, which travels through space in visible rays at the speed of light.

33
00:04:34.900 --> 00:04:39.080
Now, convection heating is like the heat from this match. It heats the air around it.

34
00:04:39.480 --> 00:04:44.720
The hot air rises and the cold air sinks, and eventually the circulating current of air heats the house.

35
00:04:45.320 --> 00:04:50.600
Now, whether you use a coal furnace, a radiator, or a forced air system,

36
00:04:51.180 --> 00:04:55.340
you are still depending upon convection currents of hot air to keep you warm.

37
00:04:56.560 --> 00:05:04.440
But Thermalux, like the sun, heats people and objects directly with invisible radiant heat.

38
00:05:08.840 --> 00:05:16.400
In other words, these two objects would be heated by the Thermalux panel,

39
00:05:16.680 --> 00:05:19.520
even though the air surrounding them were below zero.

40
00:05:19.520 --> 00:05:26.860
Now, if your eyes could see heat waves the same way they see light, the panel would look something like this.

41
00:05:27.540 --> 00:05:33.380
This scene was taken with camera film that is sensitive to otherwise invisible radiant heat rays.

42
00:05:34.800 --> 00:05:39.720
At the top, we see the Thermalux panel, and in a moment,

43
00:05:41.260 --> 00:05:47.140
the invisible rays transmit the heat to everything beneath the panel, the people, the floor.

44
00:05:47.760 --> 00:05:51.560
Everything in the room is comfortably warmed by the even radiant heat.

45
00:05:53.220 --> 00:05:57.880
Even though Thermalux is radically different from any heating system we've known in the past,

46
00:05:58.580 --> 00:06:02.100
it is more economical to install than conventional systems.

47
00:06:04.060 --> 00:06:10.380
This is the living room. You'll find for a room this size, 15 by 20, in this part of the country,

48
00:06:10.740 --> 00:06:13.820
we will need a heat output of 2,700 watts.

49
00:06:13.820 --> 00:06:21.300
Since Thermalux delivers 15 watts per square foot, this calls for 180 square feet of Thermalux panel.

50
00:06:26.960 --> 00:06:30.240
First, the electrical wiring is brought in from a branch circuit.

51
00:06:38.820 --> 00:06:48.700
From this point, the wiring will be carried to each individual Thermalux panel through an electrical raceway recessed into the ceiling.

52
00:06:58.140 --> 00:07:02.640
The base for the electrical raceway is made from half-inch gypsum filler panel.

53
00:07:30.220 --> 00:07:33.080
Thermalux panels can be cut to any desired length,

54
00:07:35.480 --> 00:07:41.580
and this special type 2 panel can also be cut to width because the heating element covers only one half of this panel.

55
00:08:07.940 --> 00:08:14.440
The panels are nailed directly to the ceiling joists with these special insulated nails.

56
00:08:16.040 --> 00:08:20.520
These nails can be driven anywhere in the panel except through the copper electrodes.

57
00:08:35.240 --> 00:08:39.500
After the Thermalux panels have been installed, the wiring can be completed.

58
00:08:40.320 --> 00:08:46.060
This special bushing anchors the branch circuit to the base of the electrical raceway.

59
00:09:05.080 --> 00:09:12.000
The copper electrodes are peeled back at the end of each panel, and the Thermalux connectors are fitted in place.

60
00:10:18.120 --> 00:10:23.640
And that's all there is to it. The electrical hookup on this panel is complete.

61
00:10:26.460 --> 00:10:29.820
From this point, the rest of the panels are simply connected in parallel.

62
00:10:47.980 --> 00:10:56.920
After the installation is inspected, the ceiling is finished with a layer of special high-density 1⁄4-inch Thermalux finishing panels.

63
00:10:58.400 --> 00:11:02.140
Then the ceiling will be ready for the conventional joint finishing and painting.

64
00:11:12.760 --> 00:11:18.240
Well, actually this Thermalux is pretty simple. It's about like lamination.

65
00:11:18.680 --> 00:11:20.740
So maybe a few extra things you have to check out.

66
00:11:21.020 --> 00:11:24.780
Thermalux was under development for five years before it was released to the market,

67
00:11:24.780 --> 00:11:31.040
and in 1961 several test installations were made in new homes and apartments in Northern Illinois.

68
00:11:32.080 --> 00:11:34.760
This is Chicago, the Windy City.

69
00:11:36.000 --> 00:11:40.520
This is the area that was selected for the field tests of actual Thermalux installations.

70
00:11:42.320 --> 00:11:46.120
The test installations were made in real homes, lived in by real people.

71
00:11:46.860 --> 00:11:49.980
They are typical houses with normal rooms, normal floor plans.

72
00:11:50.700 --> 00:11:53.520
The only difference is the heating. Thermalux.

73
00:11:53.520 --> 00:11:58.480
After three rugged Chicago winters, this was the reaction of the people involved.

74
00:11:59.420 --> 00:12:01.740
This is research engineer Tom Fitzpatrick.

75
00:12:01.800 --> 00:12:07.320
...the creation of Thermalux about the latter portion of 1961.

76
00:12:08.660 --> 00:12:16.400
At this point, we decided to install Thermalux in actual homes to get experience from people,

77
00:12:16.740 --> 00:12:20.440
to find out how their reactions would be to the heating system.

78
00:12:20.440 --> 00:12:26.080
We had proven everything in the laboratory. Now we want to get correlation data.

79
00:12:26.660 --> 00:12:33.380
One of the first trial jobs of Thermalux was the Ray Resonance in South Chicago.

80
00:12:34.820 --> 00:12:40.540
Mrs. Ray was extremely enthusiastic about the performance of the Thermalux system

81
00:12:41.400 --> 00:12:44.680
because she was primarily concerned with comfort.

82
00:12:46.360 --> 00:12:50.280
We find Thermalux heating system a very comfortable heat.

83
00:12:51.640 --> 00:12:57.140
It is a regular, even heat in every corner of the room or in the center.

84
00:12:58.540 --> 00:13:02.640
The cost of the heat we have found to be a little bit more,

85
00:13:03.260 --> 00:13:07.300
but from a woman's point of view, at the end of the year,

86
00:13:07.980 --> 00:13:11.680
the cost of cleaning draperies and upholstery and carpeting,

87
00:13:11.680 --> 00:13:15.780
I found that it really averages out.

88
00:13:18.420 --> 00:13:22.340
The Tories Resonance was selected for a few reasons.

89
00:13:23.360 --> 00:13:27.180
The first reason was the actual house construction.

90
00:13:27.600 --> 00:13:34.040
It had a very large cathedral ceiling in which we could put Thermalux

91
00:13:34.040 --> 00:13:36.840
to heat the living room and dining room area.

92
00:13:37.700 --> 00:13:41.840
The cost of electric heat was not as high as we had anticipated.

93
00:13:42.920 --> 00:13:46.320
Last winter when we had one of the most severe winters in the area,

94
00:13:46.820 --> 00:13:52.900
our bills ran an average of less than $50 per month for the entire year.

95
00:13:53.220 --> 00:13:55.180
Of course, our house is total electric.

96
00:13:55.880 --> 00:14:03.440
We have cooking, air conditioning, drying our clothes, heating our water, our own water well.

97
00:14:04.180 --> 00:14:09.520
So we have just one utility bill, and as far as comfort, what do you think, honey?

98
00:14:09.820 --> 00:14:11.140
I think it's wonderful.

99
00:14:12.720 --> 00:14:14.880
Another thing is quiet also.

100
00:14:15.120 --> 00:14:19.660
You don't have the noise of the furnace, which you have with the other heating system.

101
00:14:20.200 --> 00:14:24.680
And so you're completely unaware that you're even in a heated house.

102
00:14:24.680 --> 00:14:26.880
You feel like it's a nice warm day outside.

103
00:14:27.940 --> 00:14:33.600
The results of the Raymond House were very promising as far as we were concerned

104
00:14:33.600 --> 00:14:41.140
because the people, that is the Ravens, were extremely happy with the quiet performance of the system.

105
00:14:42.340 --> 00:14:51.860
They told us that the quiet performance was the major point as far as they were concerned with the whole heating system.

106
00:14:52.860 --> 00:15:00.220
The thing that interests me most about our electric heat is there is no noise to it.

107
00:15:00.420 --> 00:15:04.100
I very much object to extraneous noises.

108
00:15:05.440 --> 00:15:11.940
No air blowing around or no blowers grinding out like we used to have in the old gas-heated house at all.

109
00:15:12.280 --> 00:15:13.240
Just complete silence.

110
00:15:13.500 --> 00:15:14.800
Oil heat too, remember?

111
00:15:15.440 --> 00:15:15.960
Yeah.

112
00:15:17.980 --> 00:15:24.540
One thing I think that you probably would like about it too is the room-by-room control.

113
00:15:25.060 --> 00:15:28.780
You know, a guy go around at night and sneakily turn those things off a little bit?

114
00:15:29.060 --> 00:15:39.880
One of the things your friends keep being amazed at is they can't understand how the floor can be warm, so warm, when the heat's on the ceiling.

115
00:15:40.560 --> 00:15:42.420
Have you ever find a way of getting that over to you?

116
00:15:42.420 --> 00:15:43.600
No, no.

117
00:15:43.860 --> 00:15:45.000
They simply don't understand it.

118
00:15:45.180 --> 00:15:47.040
I'm not sure I do.

119
00:15:48.520 --> 00:15:52.580
People often ask us about the cost. I think it's extremely high.

120
00:15:54.540 --> 00:16:01.160
Before we built the house, we had the public service company engineers give us an estimate of the annual operating cost,

121
00:16:01.420 --> 00:16:08.260
and they come up with a figure around $350 for all use of services, I remember it.

122
00:16:08.860 --> 00:16:18.120
We fooled them. We're under $350 a year, and particularly since the last rate reduction came along, I guess it was...

123
00:16:18.120 --> 00:16:20.300
And what does Thermalux mean to you?

124
00:16:21.060 --> 00:16:24.140
If you're a builder, it means a chance to sell more houses.

125
00:16:24.600 --> 00:16:26.660
Houses with clean, quiet, flameless heat.

126
00:16:27.220 --> 00:16:30.100
A heating system with no moving parts, no maintenance.

127
00:16:31.960 --> 00:16:42.780
If you're an architect, it means a chance to design a home or apartment with a completely concealed heating system that takes up no space and allows for complete design freedom.

128
00:16:45.200 --> 00:16:55.180
And if you're a contractor, it means a chance to offer your builders the selling advantage of a cost-saving heating system that becomes as much a part of the house as the ceiling itself.

129
00:16:55.960 --> 00:17:00.880
A home with natural heat, with an independent heating system in every room.

130
00:17:02.360 --> 00:17:07.040
This is Thermalux, new, from United States Gypsum.

131
00:17:08.040 --> 00:17:12.320
Some people have called it the most startling home heating development in the last 20 years.

132
00:17:13.180 --> 00:17:15.740
When you've seen it in action, we think you'll agree.