WEBVTT

1
00:00:18.640 --> 00:00:19.640
We waited.

2
00:00:20.660 --> 00:00:23.660
We waited a long time to unveil this idea.

3
00:00:24.480 --> 00:00:28.880
We wanted to test it, check it, perfect it.

4
00:00:28.880 --> 00:00:31.800
Now the time is right, the idea is right.

5
00:00:32.140 --> 00:00:32.860
It works.

6
00:00:33.820 --> 00:00:39.340
And fitting contact lenses will never again be the same, because we've got a system.

7
00:00:49.160 --> 00:00:50.840
Health care has come a long way.

8
00:00:50.840 --> 00:00:56.160
It has become specialized, subspecialized, and super specialized.

9
00:00:59.320 --> 00:01:01.080
Certainly this is true in eye care.

10
00:01:01.900 --> 00:01:08.120
No longer need we rely upon instruments invented a century ago and virtually unchanged since.

11
00:01:09.980 --> 00:01:15.960
Today we have the tools to keep pace with our patients' needs and our needs for providing better care.

12
00:01:16.840 --> 00:01:23.420
Today we take a giant step into the age of specialization with System 2000.

13
00:01:25.280 --> 00:01:26.580
What is System 2000?

14
00:01:27.260 --> 00:01:28.880
In a word, assistance.

15
00:01:29.700 --> 00:01:31.420
Computer assistance in your practice.

16
00:01:32.180 --> 00:01:39.620
In a sentence, it's a means of photographing the cornea and measuring it with a computer to get more precise specifications.

17
00:01:39.620 --> 00:01:46.480
For a lens so comfortable, so well fitted, it can well be called the gentle lens.

18
00:01:48.860 --> 00:01:54.620
In practice, it needs you to start it, your examination and prescription for your patient's needs.

19
00:01:59.680 --> 00:02:02.500
Then System 2000 begins with a cornea.

20
00:02:03.180 --> 00:02:05.620
The cornea curves, a lens curves.

21
00:02:06.760 --> 00:02:10.220
Interrelate those curves and you've designed a perfect fit.

22
00:02:10.760 --> 00:02:12.820
Simple, not so simple.

23
00:02:13.560 --> 00:02:15.280
The cornea is not symmetrical.

24
00:02:16.040 --> 00:02:17.740
No two corneas are alike.

25
00:02:18.400 --> 00:02:23.900
And to properly design a lens, the true corneal curves must be precisely measured.

26
00:02:28.200 --> 00:02:34.860
System 2000 does it with a camera, a photo electronic keratoscope, the P.E.K. Mark III.

27
00:02:38.980 --> 00:02:44.800
The camera sees a target projected on the cornea, a contour map of the cornea.

28
00:02:45.620 --> 00:02:47.820
Where the curve is steep, the rings are small.

29
00:02:48.260 --> 00:02:51.080
Where the curve is flat, the rings are spread apart.

30
00:02:52.960 --> 00:02:56.700
The P.E.K. Mark III shows the curve completely and correctly.

31
00:02:58.820 --> 00:03:00.740
Center the image, focus.

32
00:03:01.540 --> 00:03:02.860
An exposure is made.

33
00:03:02.860 --> 00:03:08.680
And within ten seconds, a photo, a keratograph of the cornea is processed.

34
00:03:09.360 --> 00:03:12.860
This plus your reflection starts off System 2000.

35
00:03:15.120 --> 00:03:16.800
Measuring the curve comes next.

36
00:03:17.580 --> 00:03:21.320
At a Wesley Jessen visual data station, the photo is scanned.

37
00:03:22.080 --> 00:03:24.080
Distances between rings are measured.

38
00:03:25.980 --> 00:03:30.340
Readings are taken, data covering up to 28 points on each cornea.

39
00:03:32.860 --> 00:03:37.620
Then, along with your prescription, the data is translated into computer language.

40
00:03:40.640 --> 00:03:43.120
The computer is what makes System 2000 tick.

41
00:03:43.640 --> 00:03:44.600
It does the searching.

42
00:03:46.300 --> 00:03:47.540
It does the calculating.

43
00:03:48.780 --> 00:03:51.880
Making nearly a quarter million calculations in a few seconds.

44
00:03:52.920 --> 00:03:54.940
And it does the retrieving.

45
00:03:55.500 --> 00:04:00.420
Reporting back its analysis in a printout that becomes a permanent part of the patient's file.

46
00:04:00.420 --> 00:04:06.780
A printout that provides precisely controlled clearances, giving the best fit lens.

47
00:04:11.340 --> 00:04:16.100
System 2000 follows through in lens design exclusively at Wesley Jessen.

48
00:04:17.600 --> 00:04:21.460
Here, continuity is stressed with consistency throughout production.

49
00:04:22.840 --> 00:04:28.880
From formulating our own ophthalmic plastics to using special techniques and tools.

50
00:04:30.040 --> 00:04:34.860
Specially trained technicians write through our own series of 21 inspections.

51
00:04:47.560 --> 00:04:52.360
Then, along with your patient's printout and keratographs, the lenses arrive ready for fitting.

52
00:04:53.400 --> 00:04:57.800
The result? A lens so precisely measured, so carefully made.

53
00:04:57.800 --> 00:05:02.160
A lens so comfortable, we call it the gentle lens.

54
00:05:03.180 --> 00:05:07.400
And there's a lot more going for System 2000 and for your practice.

55
00:05:08.160 --> 00:05:10.220
No other procedure can equal it.

56
00:05:10.780 --> 00:05:15.200
It's fully compatible with every type of contact lens known to the profession.

57
00:05:16.020 --> 00:05:19.060
It will be the procedure of choice for years to come.

58
00:05:19.460 --> 00:05:22.900
Offering as many uses as the mind can imagine.

59
00:05:22.900 --> 00:05:27.520
System 2000. It's just the beginning.

60
00:05:52.900 --> 00:05:52.940
System 2000.