This is Gerald Berry Jr., one of the architects on the new colony of the Angel School.

2
00:02:41.480 --> 00:02:49.200
Mr. Berry, as I understand it, the new school will not have a sprinkler system throughout as the new Chicago ordinance has called for.

3
00:02:49.260 --> 00:02:49.980
Why is that?

4
00:02:50.160 --> 00:02:57.340
The principal reason that this school doesn't have total sprinkling comes from the fact that it is a fire resistant structure

5
00:02:57.340 --> 00:03:00.340
provided by the city of Chicago's Class A.

6
00:03:01.460 --> 00:03:06.680
Sprinklers are provided in all unoccupied areas of the school.

7
00:03:06.880 --> 00:03:12.660
The boiler room, storage rooms, and the waste paper and incinerator rooms,

8
00:03:12.960 --> 00:03:20.080
but are not used in the classrooms or corridors or stair halls because they are normally occupied during the school day.

9
00:03:20.080 --> 00:03:26.460
This was approved by the city of Chicago when they approved the drawings of the building for construction.

10
00:03:28.300 --> 00:03:34.100
Well, has the city dispensed already the angels from putting in a complete sprinkler system as the new ordinance calls for?

11
00:03:35.300 --> 00:03:40.580
The building, as you see it here, was approved for construction without total sprinkling.

12
00:03:40.880 --> 00:03:43.120
Since the new ordinance was passed earlier this year.

13
00:03:43.220 --> 00:03:43.760
That's correct.

14
00:03:43.760 --> 00:03:52.040
Well, as I understand it, only about a dozen schools in Chicago have complied with the ordinance calling for sprinkling systems throughout.

15
00:03:52.820 --> 00:03:57.320
Now, will other schools be able to get by without putting in the sprinkling system also?

16
00:03:58.240 --> 00:03:59.840
I can't answer that question.

17
00:04:00.640 --> 00:04:06.700
Each school, I think, is a problem of itself and will have to be settled on its own merits.

18
00:04:08.880 --> 00:04:15.280
Mr. Berry, could you tell me what is being done to make this new alley of the Angel School safe from fire?

19
00:04:16.020 --> 00:04:22.140
The new Lady of Angel School is about the most fire-resistant structure that I know of.

20
00:04:22.700 --> 00:04:26.980
It's a building that is built completely of reinforced concrete.

21
00:04:27.700 --> 00:04:34.680
The walls, the floors, the structural framing system are all of the concrete variety.

22
00:04:34.680 --> 00:04:42.640
We have curtain wall construction here, which means that the exterior walls are of metal and glass.

23
00:04:44.360 --> 00:04:46.680
The classroom partitions...

24
00:04:52.720 --> 00:04:57.860
Mr. Berry, what is being done to make the new Lady of the Angel School safe from fire?

25
00:04:57.860 --> 00:05:06.200
I believe that the fire safety of this structure is rather apparent from the structure as you see it standing behind us.

26
00:05:06.820 --> 00:05:11.800
As you can see, all of the structural framing numbers are of reinforced concrete.

27
00:05:12.380 --> 00:05:15.380
The floor slabs, the ceilings are of reinforced concrete.

28
00:05:16.120 --> 00:05:24.500
At the time that the building will be completed, the interior walls will all be of concrete block painted with a fire-resistant paint.

29
00:05:24.500 --> 00:05:28.300
The trim is limited to non-combustible material.

30
00:05:30.140 --> 00:05:40.640
We have installed sprinkler, alarm, and detecting systems in all unoccupied areas, such as storage rooms, boiler rooms, waste paper storage, and incinerator rooms.

31
00:05:41.780 --> 00:05:49.420
We have the manual alarm system to give the alarm in case of fire or any other emergency requiring evacuation of the building.

32
00:05:49.640 --> 00:05:51.340
There will be fire alarm systems throughout the building?

33
00:05:51.340 --> 00:05:52.100
That's correct.

34
00:05:52.340 --> 00:06:04.780
And we have provided a number of stairways for vertical exits from the building so that there should be no reason that any student would be hampered in his egress from the building in case of an alarm.

35
00:06:04.960 --> 00:06:06.920
Will stairwells have fire doors?

36
00:06:07.120 --> 00:06:17.920
The stairwells will be enclosed by fire doors, and they will be totally fire resistant and are called fire towers in the terminology that we use,

37
00:06:17.920 --> 00:06:24.140
because they are totally isolated from the building and therefore provide safe exits from each floor.

38
00:06:25.180 --> 00:06:26.120
This school will be safe.

39
00:06:26.380 --> 00:06:28.300
The school will be extremely safe.

40
00:06:28.780 --> 00:06:30.380
Thank you.

41
00:06:31.040 --> 00:06:32.760
Now back to John in New York.

42
00:06:37.280 --> 00:06:44.700
A year ago today, classes at our Lady of the Angels Elementary parochial school, which stood here on this site, were preparing for dismissal.

43
00:06:44.700 --> 00:06:58.780
Suddenly a terrible fire started, believed to have begun at the bottom of a basement stairwell, and it flashed up immediately in seconds almost to a second story classroom on the north wing over to your left.

44
00:06:59.620 --> 00:07:05.380
There, 95 persons, 92 students, and three teachers were burned to death.

45
00:07:07.520 --> 00:07:13.420
Now a new building is being built on the site, a brand new Our Lady of the Angels School.